Piezo Scaler Tips

By professionals for professionals

The enhanced W&H piezo scaler tip range includes different tips for prophylaxis and periodontology, endodontics, implantology and restoration & prosthetics. The W&H range of tips for the piezo scaler Tigon+, Proxeo Ultra and Pyon 2 were developed in close cooperation with end users. The range therefore fulfils the exact requirements of dental practice and implantology.

  • Piezo tips for Prophylaxis

    Tip 1U / 1UQ / 1US

    • Removal of supragingival calculus in all quadrants
    • The entire treatment can be carried out without the tedious job of changing tips

    Tip 2U / 2UQ / 2US

    • Visibly longer and narrower 2U tips
    • Treatment of recall patients
    • For fine finishing
    • Fine scaling of supragingival calculus
    • Removal of plaque

    Tip 3U / 3UQ / 3US

    • Slightly rounded and also particularly narrow and short
    • Fine scaling in the supragingival region
    • Ideal instrument for cleaning the interdental spaces

    Tip 4U

    • Perfect tip for removing large areas of calculus

    Piezo tips for implant cleaning

    Tip 1I / 1IQ Implant-clean

    • Cleaning of implants
    • Associated suprastructures and restorations

    Piezo tips for Periodontology

    Tip 1P / 1PQ / 1PS

    • Removal of concretions in the subgingival region
    • Especially suitable for the treatment of deep periodontal pockets

    Tip 3Pr / 3PrQ

    • Right-curved tip for periodontal debridement
    • Recommended for maintenance treatment on medium-depth to deep pockets as well as furcations

    Tip 3PI / 3PIQ

    • Left-curved tip for periodontal debridement
    • Recommended for maintenance treatment on medium-depth to deep pockets as well as furcations

    Tip 4P / 4PQ / 4PS

    • Diamond-coated tip for cleaning the root surface

    Tip 5Pr / 5PrQ

    • Right-curved tip with diamond coating for cleaning the root surface

    Tip 5PI / 5PIQ

    • Left-curved tip with diamond coating for cleaning the root surface

    Tip 5P / 5PQ

    • Diamond-coated tip for cleaning furcations and concavities

    Piezo tips for Restoration

    Tip 1R

    • Expanding of fissures

    Tip 2R

    • Diamond-coated tip for veneer preparation
    • For clearly defined preparation margins
    • Maximum protection of the gingiva and the neighbouring tooth

    Tip 3Rm

    • Part-diamond tips for finishing approximal mesial cavity edges

    Tip 3Rd

    • Part-diamond tips for finishing approximal distal cavity edges

    Piezo tips for Endodontics

    Tip 1E / 1ES

    • Non-cutting instrument for effective rinse activation in the root canal system

    Tip 2E

    • Tip for lateral thermal condensation of gutta-percha

    Tip 3E

    • Removing of broke instruments in the root canal

    Tip 4E

    • Preparation of the pulp chamber

    Tip 5E

    • Vibrating and removal of root canal posts

    Tip 6E

    • Removal of root canal fillings and root canal calcifications

    Download Area

    Poradniki video

    W celu bezproblemowego i interaktywnego korzystania z naszych treści multimedialnych (np. filmów, map) w trybie online, prosimy o wyrażenie zgody na przechowywanie niezbędnych plików cookie (YouTube, MovingImage - szczegółowe informacje na temat plików cookie można znaleźć w formularzu o ochronie danych) w celach marketingowych.

    akceptuję
  • Compatibility of tips with W&H handpieces

    Q-Link* W&H/EMS/Mectron W&H/NSK/Satelec**
    PB-5 L Q PB-5 L PA-1 LED PB-3 PB-5 L S PB-3 LED S PB-3 S
    Tigon+

    X

    X

    Proxeo Ultra

    X

    X

    X

    Pyon 2

    X

    Built-In

    X

    X

    X

    X

    X

    * Q-Link tips (e.g., 1UQ, 2UQ) are compatible with the PB-5 L Q.
    ** W&H tips with Satelec thread (e.g., 1US, 2US) are compatible with the W&H handpieces PB-5 L S, PB-3 LED S and PB-3 S.
    Note: EMS®, Mectron®, NSK® and Satelec® are trademarks of third parties not affiliated with W&H Dentalwerk Bürmoos GmbH. When using tips from other manufacturers, the user is responsible for ensuring the W&H piezo device´s performance parameters are set correctly.